EI、Scopus 收录
中文核心期刊
CONCENTRATION MEASUREMENT AND ITS TWO-DIMENSIONAL DIGITAL CALIBRATION BY A PLIF TECHNIQUE[J]. Chinese Journal of Theoretical and Applied Mechanics, 1994, 26(5): 616-624. DOI: 10.6052/0459-1879-1994-5-1995-588
Citation: CONCENTRATION MEASUREMENT AND ITS TWO-DIMENSIONAL DIGITAL CALIBRATION BY A PLIF TECHNIQUE[J]. Chinese Journal of Theoretical and Applied Mechanics, 1994, 26(5): 616-624. DOI: 10.6052/0459-1879-1994-5-1995-588

CONCENTRATION MEASUREMENT AND ITS TWO-DIMENSIONAL DIGITAL CALIBRATION BY A PLIF TECHNIQUE

  • The fluorescence intensity distributions in water tank are obtained for con-centration measurement by a PLIF technique, and a two-dimensional digital calibrationequation and method are then proposed in order to account for the nonuniform distributionand attenuation of intensity of a laser thin. Based on the above,the concentration field ofround turbulent jet is measured and calibrated. Finally, the results of jet are analyzed andcompared with those of the semi-empirical theory.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return